The AFP-200 is a versatile analog fire control panel, offering robust features and reliable performance. Detailed installation manuals and datasheets are readily available as PDF downloads.
Overview of the AFP-200 System
The AFP-200 system represents a significant advancement in fire alarm technology, providing comprehensive life safety protection. This analog addressable panel supports up to 198 intelligent devices, encompassing 99 analog detectors and 99 monitor/control modules, achieving an overall point capability of 301. It’s designed for adaptability, supporting Style 4, 6, or 7 wiring configurations.
The system’s functionality is enhanced through features like Read Status, enabling detailed system monitoring. Supplemental documentation, including the installation manual and HBT Fire 351608 datasheet, provides crucial guidance. The AFP-200’s architecture ensures reliable operation and ease of integration within diverse fire protection schemes.
Key Features and Capabilities
The AFP-200 boasts a high intelligent device capacity – 198 total (99 detectors, 99 modules) – and a 301-point overall capability. Flexible style configurations (4, 6, or 7) cater to diverse installation needs. A crucial feature is the ‘Read Status’ functionality, accessed via specific instructions detailed in Table 3.1, allowing for comprehensive system diagnostics.
Furthermore, the system supports integration with monitor/control modules, RTM-8, and 4XTM devices. The panel’s compatibility extends to intelligent detectors, and detailed wiring diagrams are available for NAC connections. Access to the FS-8700-26 driver (version 1.02) facilitates seamless software integration.

Understanding the AFP-200 Components
The AFP-200 system comprises control panel hardware and supports various addressable devices. Refer to the detailed datasheets, like HBT Fire 351608, for specifics.
Control Panel Hardware
The AFP-200’s control panel hardware forms the central hub of the fire alarm system, managing all connected devices and providing a user interface for monitoring and control; It’s designed for flexibility, supporting a substantial intelligent device capacity – up to 198 devices, encompassing 99 analog detectors and 99 monitor/control modules.
This hardware facilitates style 4, 6, or 7 operation, offering adaptable configurations to suit diverse building requirements. The panel boasts an overall point capability of 301 points, ensuring comprehensive coverage. Understanding the panel’s physical dimensions and weight, as detailed in the technical specifications, is crucial for proper installation and mounting.
Addressable Devices Supported
The AFP-200 expertly supports a wide array of addressable devices, enhancing system precision and control. It seamlessly integrates with intelligent detectors, up to 99 units, allowing for pinpoint identification of fire locations. Furthermore, the system is compatible with monitor/control modules, also up to 99, expanding its capabilities beyond simple detection.
Crucially, the AFP-200 demonstrates compatibility with both RTM-8 and 4XTM modules, broadening device options. Proper programming of these devices, including municipal box data, is essential for optimal functionality. The system’s architecture allows for flexible configurations, supporting Style 4, 6, or 7 wiring.
Notifier AFP-200 Data Sheet Details
The AFP-200 Data Sheet (DN-3783) provides critical system connection information, including a basic system drawing for simplified installation. It details wiring diagrams and instructions, specifically for NAC (Notification Appliance Circuit) connections, outlining the proper sequence for reliable operation. The datasheet also clarifies the application of Reverse Polarity Output values, essential when integrating RTM-8, 4XTM, and Municipal modules;
Furthermore, the document outlines the panel’s overall 301-point capability, encompassing 198 intelligent devices – 99 detectors and 99 monitor/control modules – ensuring comprehensive fire protection. Accessing this datasheet is vital for correct setup and troubleshooting.

Installation Procedures
Proper installation requires careful attention to mounting, wiring, and system connections, as detailed in the AFP-200 installation manual and associated datasheets.
Mounting and Wiring Requirements
Secure mounting is crucial for the AFP-200’s reliable operation. The panel should be installed within an easily accessible location, adhering to all local and national fire codes. Wiring must conform to relevant standards, utilizing appropriately sized conductors for all connections.
Carefully follow the wiring diagrams provided in the installation manual, paying close attention to polarity and grounding requirements. Ensure all connections are tight and secure to prevent signal interference or system malfunctions. Proper wire labeling is essential for future troubleshooting and maintenance. The AFP-200 Data Sheet provides specific guidance on wiring configurations.
NAC Wiring Diagrams and Instructions
Notification Appliance Circuit (NAC) wiring for the AFP-200 requires meticulous attention to detail. The system supports various wiring styles – Style 4, 6, or 7 – each with specific wiring configurations. Consult the installation manual for detailed diagrams illustrating these styles.
Connect the NAC according to the chosen style, ensuring proper end-of-line resistor values are used. Incorrect wiring can lead to false alarms or system failures. The AFP-200 Data Sheet outlines the recommended wiring practices and provides clear instructions for connecting devices to the NAC. Verify all connections before powering up the system.
System Connections – Basic System Drawing
The AFP-200 utilizes a modular design, allowing for flexible system configurations. A basic system drawing, detailed in the AFP-200 Data Sheet (DN-3783), illustrates typical connections. This includes the control panel itself, addressable devices (detectors, modules), and the NAC circuits.
Connections involve wiring initiating devices and notification appliances back to the control panel. Proper grounding and wiring practices are crucial for reliable operation. The drawing serves as a visual guide for installers, demonstrating the fundamental architecture of an AFP-200 fire alarm system. Refer to the manual for expanded system examples.

Programming and Configuration
AFP-200 programming involves entering municipal box data and configuring device capacity. Style configuration (4, 6, or 7) is essential for system functionality.
Entering Device Data (Municipal Box Data)
Entering municipal box data into the AFP-200 is a crucial step during system configuration. This data, obtained from the municipal box datasheet, allows the panel to correctly interface with local emergency services. The process involves utilizing Calculation Column 2 to input the current values accurately.
Proper data entry ensures seamless communication during alarm events, facilitating a swift and coordinated response. Incorrect data can lead to communication failures, potentially compromising safety. Refer to the AFP-200 installation manual for detailed, step-by-step instructions on navigating the programming interface and correctly inputting this vital information.
Programming Intelligent Device Capacity
The AFP-200 boasts an impressive intelligent device capacity, supporting up to 198 devices – specifically, 99 analog detectors and 99 monitor/control modules. Programming this capacity within the panel is essential for optimal system performance and to prevent communication errors. This configuration ensures the system accurately recognizes and processes signals from all connected intelligent devices.
Refer to the installation manual for detailed instructions on accessing the programming menu and setting the appropriate device limits. Correctly programming the capacity guarantees the system functions as designed, maximizing its effectiveness in detecting and responding to fire events.
Style Configuration (Style 4, 6, or 7)
The AFP-200 fire alarm control panel supports multiple signaling line circuit (SLC) styles: 4, 6, and 7. Style 4 offers a single wire with a ground return, while Style 6 utilizes a double wire with no ground return, providing increased reliability. Style 7 employs a double wire with a ground return, offering the highest level of fault tolerance.
Selecting the appropriate style depends on the specific application and desired level of protection. Refer to the installation manual for detailed guidance on configuring the SLC style and understanding the implications of each choice. Proper style configuration is crucial for ensuring dependable fire detection.

Operation and Monitoring
The AFP-200 allows for “Read Status” functionality, detailed in Table 3.1 of supplemental documentation, to efficiently monitor system health and device status.
Read Status Functionality
The AFP-200’s Read Status feature is a crucial diagnostic tool for technicians. It allows for comprehensive interrogation of the fire alarm system, providing detailed information about each device connected to the loop. To initiate a Read Status, consult Table 3.1 within the supplemental documentation provided by Notifier.
This process reveals the current status of each initiating device – normal, alarm, trouble, or disabled – and provides valuable data for troubleshooting. Understanding the Read Status output is essential for efficient system maintenance and rapid fault identification, ensuring optimal fire protection performance. It’s a cornerstone of effective system operation.
Controls and Indicators Explained
The AFP-200 control panel features a user-friendly interface with various controls and indicators. These provide essential system status information at a glance. The panel’s indicators display system power, alarm, trouble, and supervisory conditions. Controls allow for acknowledging alarms, silencing audible signals, and initiating system tests.
Understanding the meaning of each illuminated indicator and the function of each control is vital for proper operation. Refer to the installation manual for a detailed explanation of each element. Proper interpretation ensures swift response to fire events and efficient system management, maximizing safety and minimizing downtime.
Overall Point Capability (301 Points)
The AFP-200 fire alarm control panel boasts an impressive overall point capability of 301 points. This capacity is achieved through a combination of intelligent devices, supporting up to 198 intelligent devices – specifically, 99 analog detectors and 99 monitor/control modules. This substantial capacity allows for comprehensive fire detection and notification coverage in a wide range of facilities.
The remaining points are allocated for other system components, ensuring a scalable and adaptable solution. This high point capacity makes the AFP-200 suitable for both small and large applications, offering flexibility and future expansion possibilities.

Troubleshooting Common Issues
AFP-200 troubleshooting involves identifying and resolving faults, understanding error messages, and addressing reverse polarity output values as detailed in provided documentation.
Identifying and Resolving Faults
Effective fault resolution with the AFP-200 begins with a systematic approach. Utilize the panel’s “Read Status” functionality to pinpoint the source of the issue, referencing Table 3.1 for detailed instructions. Common faults include wiring problems, device malfunctions, or programming errors.
Carefully inspect all connections and wiring diagrams. If a device is identified as faulty, replace it with a compatible component. Programming errors can often be corrected by reviewing and adjusting device data, ensuring accurate municipal box information is entered. Always consult the installation manual and datasheets for specific guidance on troubleshooting procedures and error code interpretations.
Reverse Polarity Output Values
Understanding reverse polarity is crucial when integrating the AFP-200 with specific devices. These output values are particularly relevant when utilizing RTM-8, 4XTM, and municipal boxes within the fire alarm system. The documentation specifies that these values apply directly to the operation of these connected modules.
Incorrect polarity can lead to communication errors or device malfunction. Always verify wiring configurations against the provided diagrams and datasheets. Ensure proper connections are made to avoid unintended consequences; Refer to the calculation columns within the manual for accurate reverse polarity values, ensuring system reliability and compliance.
Understanding Error Messages
The AFP-200 utilizes a comprehensive error messaging system to aid in troubleshooting and system maintenance. These messages, displayed on the control panel, provide valuable insights into potential faults or malfunctions within the fire alarm system. Proper interpretation of these messages is essential for efficient diagnostics.
Refer to the installation manual for a detailed explanation of each error code and its corresponding resolution. Common issues may include communication failures, device tampering, or power supply problems. Addressing these errors promptly ensures continued system reliability and adherence to safety standards. Always document error occurrences for future reference.

Technical Specifications
The AFP-200 boasts a 301-point capability, supports 198 intelligent devices, and adheres to relevant agency listings for compliance and safety.
Power Requirements
The AFP-200 fire alarm control panel operates on a 24VDC power supply. It’s crucial to utilize a listed fire alarm power supply capable of delivering the necessary current to support all connected devices. The panel requires a minimum of 6.0 amps for a fully loaded system, encompassing all initiating devices, notification appliances, and communication modules.
A secondary, independent battery backup system is essential for uninterrupted operation during power outages. The battery should be a sealed lead-acid type, sized appropriately to provide at least 24 hours of standby power. Regular battery testing and maintenance, as outlined in the installation manual, are vital for ensuring system reliability. Proper grounding is also paramount for safe and effective operation.
Agency Listings and Compliance
The AFP-200 fire alarm control panel is designed and manufactured to meet stringent industry standards for safety and performance. It carries UL Listing (Underwriters Laboratories) signifying compliance with UL 864, the Standard for Fire Alarm Control Units. Furthermore, the panel meets the requirements of NFPA 72 (National Fire Protection Association), the National Fire Alarm and Signaling Code.
Compliance ensures the system’s reliability and proper functionality in life safety applications. The panel also adheres to relevant FCC (Federal Communications Commission) regulations regarding electromagnetic interference. Installation must be performed by qualified personnel to maintain these listings and ensure adherence to local codes and regulations.
Physical Dimensions and Weight
The AFP-200 fire alarm control panel is designed for practical installation within various building environments. Its cabinet dimensions are approximately 16.5 inches (419.1 mm) in width, 12.75 inches (323.85 mm) in height, and 4.5 inches (114.3 mm) in depth. These dimensions allow for flexible mounting options, accommodating standard electrical cabinet sizes.
The panel’s weight, without batteries or optional modules, is approximately 14 pounds (6.35 kg). This relatively lightweight design simplifies handling during installation and maintenance. Detailed dimensional drawings are available within the official installation manual PDF for precise planning and mounting considerations.

Software and Drivers
FS-8700-26 is the dedicated driver for the AFP-200/300/400 series, currently at Version 1.02, Revision 6, facilitating seamless system integration and control.
FS-8700-26 Driver Information
The FS-8700-26 driver is specifically designed for compatibility with the Notifier AFP-200, AFP-300, and AFP-400 fire alarm control panels. Currently, the driver is operating at Version 1.02, with Document Revision 6 representing the latest updates and improvements. This driver facilitates communication between the fire alarm panel and a host system, enabling remote monitoring, control, and data acquisition.
The driver manual provides a comprehensive table of contents, detailing installation procedures, configuration settings, and troubleshooting guidance. Proper installation of the FS-8700-26 driver is crucial for ensuring reliable system operation and maximizing the functionality of the AFP-200 series panels. Refer to the official documentation for detailed instructions and support.
Driver Version and Revision History
The FS-8700-26 driver for the Notifier AFP-200 series currently stands at Version 1.02, documented under Revision 6. While detailed historical records of prior revisions aren’t readily available in the provided snippets, this current version signifies the latest refinements and bug fixes implemented by Notifier.
Users should always ensure they are utilizing the most up-to-date driver version to benefit from enhanced stability, compatibility, and performance. Regularly checking for updates through official Notifier channels is recommended. The driver manual accompanying Version 1;02, Revision 6, details all functionalities and addresses known issues, providing comprehensive support for system integrators and end-users.

Supplemental Documentation
Additional resources include the complete installation manual available as a PDF download, and the HBT Fire 351608 Datasheet, offering detailed specifications.
Installation Manual (PDF Download)
The Notifier AFP-200 Analog Fire Control Panel Installation Manual is freely accessible in PDF format through Fire Alarm Resources. This comprehensive document provides step-by-step guidance for installers, covering all aspects of the system’s setup.
It details mounting procedures, wiring requirements for both the control panel and associated devices, and crucial system connection information. Users will find valuable NAC wiring diagrams and instructions for proper implementation. The manual also clarifies how to interpret system status and troubleshoot potential issues, ensuring a smooth and compliant installation process. Download it today for a successful setup!
HBT Fire 351608 Datasheet
The HBT Fire 351608 datasheet serves as supplemental information to the primary AFP-200 installation manual. Spanning four pages, this document provides detailed technical specifications and supporting data for specific components used within the Notifier system.
It’s a valuable resource for understanding the intricacies of the system’s operation and ensuring compatibility between various modules. While not a replacement for the main manual, the datasheet offers focused insights into particular aspects of the AFP-200’s functionality, aiding in precise configuration and effective troubleshooting during installation and maintenance.
Advanced Features
The AFP-200 supports integration with monitor/control modules, and is compatible with RTM-8 and 4XTM devices, alongside 99 intelligent detectors.
Monitor/Control Module Integration
The AFP-200 seamlessly integrates with a variety of monitor and control modules, expanding system flexibility and functionality. These modules allow for supervision of diverse inputs, including waterflow switches, tamper switches, and duct smoke detectors. Control modules enable activation of auxiliary devices like door releases or HVAC shutdown systems.
The system supports up to 99 monitor/control modules, contributing to the overall 301-point capability of the panel. Proper configuration within the panel’s programming ensures correct operation and reporting of monitored or controlled devices. Refer to the installation manual for detailed wiring diagrams and programming instructions specific to each module type. Successful integration enhances the AFP-200’s ability to provide comprehensive fire protection.
RTM-8 and 4XTM Compatibility
The AFP-200 demonstrates full compatibility with both the RTM-8 and 4XTM remote terminal modules, significantly extending the system’s input/output capacity and geographical coverage. These modules facilitate the connection of numerous devices, including detectors, notification appliances, and control relays, over a single SLC loop.
Crucially, Reverse Polarity Output values are applicable when utilizing RTM-8 and 4XTM modules. Careful attention to these values, as detailed in the municipal box data sheet, is essential for correct operation. Proper wiring and programming, as outlined in the installation manual, ensure seamless communication and reliable performance of these expanded system components.
Intelligent Detector Support (99 Devices)
The AFP-200 fire alarm control panel boasts impressive intelligent device capacity, supporting up to 99 addressable detectors. This allows for precise identification of fire locations and minimizes false alarms through advanced algorithms. Compatibility extends to a wide range of Notifier detectors, ensuring flexibility in system design.
Alongside the detector support, the system also accommodates 99 monitor/control modules. This combined capacity of 198 intelligent devices provides comprehensive fire protection. Proper programming of device data, including municipal box information, is crucial for optimal performance, as detailed within the installation manual and associated datasheets.

Maintenance and Testing
Regular inspections and functional testing are vital for ensuring the AFP-200 system’s reliability. Battery backup systems require periodic checks for optimal performance.
Regular Inspection Procedures
Consistent inspections are crucial for maintaining the AFP-200 fire alarm system’s effectiveness. Visually examine the control panel for any physical damage or obstructions, ensuring clear access to controls. Verify that all wiring connections remain secure and undamaged. Inspect the battery backup system, checking for corrosion and proper voltage levels.
Confirm that all initiating devices – detectors and pull stations – are free from obstructions and appear undamaged. Review the system event log for any recent trouble or alarm conditions. Document all inspection findings, noting any corrective actions taken. Adhering to a scheduled inspection routine, typically monthly or quarterly, ensures optimal system readiness and compliance with fire safety regulations.
Testing System Functionality
Thorough system testing validates the AFP-200’s operational integrity. Perform a walk test, activating each initiating device (detector, pull station) to confirm proper signal transmission and alarm annunciation at the panel and remote locations. Verify that notification appliance circuits (NACs) activate as programmed, ensuring audible and visual alarms are clearly discernible.
Test the communication link to any central station monitoring service. Document all test results, including dates, times, and any discrepancies encountered. Address any failures immediately. Regular functional testing, ideally semi-annually, confirms the system’s ability to respond effectively to fire events, safeguarding lives and property.
Battery Backup System Checks
Regular battery checks are crucial for ensuring uninterrupted operation during power outages. Inspect battery connections for corrosion and tightness. Perform a load test to verify the batteries’ ability to supply power for the required duration, typically 24 hours. Monitor battery voltage regularly; a significant drop indicates potential failure.
Document all test results and replace batteries as needed, adhering to manufacturer recommendations. A properly maintained battery backup system guarantees the AFP-200 continues to protect the facility even when primary power is unavailable, maintaining life safety and property protection.